Paramount Theatre

Rigging & Lineset Plot


Rigging and Lineset Plot

This lineset plot is considered the House plot.
Let us know in advance if you plan to alter it.

Line #
Distance from Plaster Line
House Use
1 1'-8" Main Valance
2 2'-5" Main Drape
3 3'-1" 1st Electric
4 4'-5" Open Line Set
5 5'-1" Open Line Set
6 6'-5" No. 1 Border
7 7'-1" No. 1 Legs
8 9'-1" Open Line Set
9 9'-9" No. 2 Border
10 10'-5" No. 2 Legs
11 11'-9" 2nd Electric
12 13'-1" Open Line Set
13 15'-1" No. 3 Border
14 15'-9" Mid stage Traveler
15 19'-1" 3rd Electric
16 20'-5" Open Line Set
17 21'-1" No. 4 Border
18 22'-5" No. 4 Legs
19 23'-9" 4th Electric
20 26'-5" Upstage Traveler
21 29'-1" Cyclorama

The locking rail is located Stage Left 28'-8" above the deck.
The fly system is single purchase with an arbor capacity of 1,200 pounds.
The House has 10,000 pounds of stage weight. This includes pipe weight for all house battens.
All battens are 44' long and 1 1/2" i.d. with 5 pick up lines per batten.
The maximum out trim of battens is 51'-4".
The Main Drape can be used as a traveler or guillotine.